Regulador de proceso electroneumático digital SideControl

Type 8793 / Ident No. 239098

Produkt-Foto Typ 8793

The depiction of the products may differ from the actual specific design.

  • Produkt-Foto Typ 8793
  • Produkt-Foto Typ 8793
  • 8793-239098-Side-Control-PID-ohne-DeviceNet-26-Isometrisch-drawing-back_thumb.png
  • 8793-239098-Side-Control-PID-ohne-DeviceNet-26-Isometrisch-drawing-bottom_thumb.png
  • 8793-239098-Side-Control-PID-ohne-DeviceNet-26-Isometrisch-drawing-drawing-6-views-eu_thumb.png
  • 8793-239098-Side-Control-PID-ohne-DeviceNet-26-Isometrisch-drawing-left_thumb.png
  • 8793-239098-Side-Control-PID-ohne-DeviceNet-26-Isometrisch-drawing-right_thumb.png


Process controller side namur

  • Forma constructiva compacta y robusta
  • Puesta de servicio mediante función Tune de reguladores de posición y de proceso
  • Funciones de diagnóstico integradas para el monitoreo de la válvula (opcional)
  • Sistema de ajuste dinámico sin consumo de aire en estado compensado por la regulación
  • Profibus DPV1 o DeviceNet (opcional)

For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

Product description

El regulador de proceso robusto y compacto está diseñado para el montaje en accionamientos lineales y rotativos con normalización según IEC 534-6 o VDI/VDE 3845. La variante con transductor de desplazamiento remoto se puede emplear también para la regulación de válvulas reguladoras de proceso de Bürkert. El regulador de proceso electroneumático digital SideControl procesa todas las señales de corriente y de tensión habituales y se puede equipar opcionalmente con una interfaz de bus de campo PROFIBUS DPV1 o DeviceNet. El valor real del parámetro de proceso se suministra al equipo directamente como 4-20 mA, Pt 100 o señal de frecuencia. De la comparación nominal-real, el regulador de proceso calcula el valor nominal interno para el regulador de posición subordenado. La parametrización de reguladores de proceso y de posición se realiza automáticamente. En este proceso, el tipo del tramo de regulación se detecta automáticamente y se determina la estructura apropiada del regulador con el juego de parámetros óptimo correspondiente. El regulador de proceso está equipado con funciones de diagnóstico adicionales para el monitoreo de la válvula. Los mensajes de diagnóstico de la válvula mediante señales de estado se realizan según NE107 (NAMUR) y se registran como entradas de historial. Con el diagnóstico se pueden monitorizar las condiciones de funcionamiento de la válvula reguladora, lo que en caso necesario hace posible la planificación de las decisiones de mantenimiento y optimiza la disponibilidad de las instalaciones. El manejo se realiza a través del módulo de mando y de indicación exterior compuesto por una pantalla gráfica con retroiluminación y un teclado de láminas robusto con cuatro teclas y denominación de funciones guiada por software. Esto ofrece al usuario un manejo muy sencillo y claro, idéntico al de los reguladores de posición o de proceso TopControl 8692/8693. El sistema de ajuste neumático se puede utilizar tanto para accionamientos de simple o doble efecto. Destaca por un comportamiento de seguridad definido en caso de avería de la energía auxiliar eléctrica o neumática y dispone de un rango de potencia de aire útil muy grande en caso de presiones de alimentación de hasta 7 bares.


Commodity Codes
90328900
país
DE

Technical attributes

Nombre
Value
Unit
Type 8793
Function Controlador de procesos
Valve function 1 manual actuation No
Pneumatic function 1 double acting Si
Pneumatic function 1 single acting Si
QNn value 1 (gas) 100 l/min
Temperature environment min 0 °C
Temperature environment max 60 °C
Displacement transducer type interno rotativo
Displacement transducer signal Potenciómetro
Positioning system with booster function No
For Actuator size 40 mm No
For Actuator size 50mm No
For Actuator size 63mm No
For Actuator size 70mm No
For Actuator size 80mm No
For Actuator size 90mm No
For Actuator size 100mm No
For Actuator size 125mm Si
For Actuator size 130mm Si
For Actuator size 175mm Si
For Actuator size 225mm Si
Port connection 1 type Rosca interior
Port connection 1 thread type G
Port connection 1 thread marking 1/4
Port connection 2 type Rosca interior
Port connection 2 thread type G
Port connection 2 thread marking 1/4
Port connection 3 type Rosca interior
Port connection 3 pre-mounted Tapón ciego
Port connection 3 thread type G
Port connection 3 thread marking 1/4
Electrical connection sort Conector
Electrical connection material Acero inoxidable
Voltage 1 / rated voltage 24 V
Voltage 1 / rated voltage 24 V
Supply system-internal No
Supply via BUS No
Supply via separating barrier No
AC voltage No
DC voltage Si
Input 1 type digital serial (bus)
Input 2 type digital transistor connection NPN No
Input 2 type digital transistor connection PNP Si
Output 2 digital transistor connection NPN No
Output 2 digital transistor connection PNP Si
Output 3 digital transistor connection NPN No
Output 3 digital transistor connection PNP Si
Communication interface protocol DeviceNet
Control interface Teclado y pantalla interno
Mounting type NAMUR / IEC 534 - 6 / VDI/VDE 3845
Protection type (IP max. with suitable connector) 65/67
Weight 1,030000 kg
Weight 1,030000 kg
Certification type
Certification number
Show full table Collapse table

Applications & Tools

CAD Model

Cookies must be enabled to use this function. Please accept cookie privacy policy first.


Downloads

Desrcripción
Filename
Filesize
Language / Country
SOW Init Files EDS GSD EDD A.04 00675717_008792_KONF_D.zip 34,2 kB
SOW Buerkert Communicator 2.3 00689176_BuerkertCommunicator_2_3.zip 44,8 MB
DTS 8681, 869x, 879x Adaptionen DS8681-InstallKits-DE-DE.pdf 4,3 MB DE / DE
DTS 8681, 869x, 879x Install Kits DS8681-InstallKits-EU-EN.pdf 4,3 MB EN / EU
DTS Controlador Proceso Side Cont DS8793-ProcessCont-ES-ES.pdf 4,1 MB ES / ES
DTS Prozessregler SideControl DS8793-Standard-DE-DE.pdf 1,1 MB DE / DE
DTS Process Controller SideControl DS8793-Standard-EU-EN.pdf 1,1 MB EN / EU
0 Flyer SideControl Types 8791, 8792 and 8793 214,3 kB EN / EU
MAN Config. PROFIBUS by GSD-file MA8644-Supplement-EU-ML.pdf 4 MB EN,FR,DE / EU
MAN Konfig.- und Parametrier Tool MA8692-Ergaenzung-EU-ML.pdf 2,8 MB EN,FR,DE / EU
MAN USB-Interface MA8694-Supplement-EU-ML.pdf 2 MB EN,FR,DE / EU
MAN Additional Information Ex MA8791-Supplement-EU-ML.pdf 222,3 kB EN,FR,DE / EU
MAN Elektropneum.Positioner MA8792-Quickstart-DE-DE.pdf 4,1 MB DE / DE
MAN Electropn. position controller MA8792-Quickstart-EU-ML.pdf 4 MB EN / EU
MAN Positionneur et régulateur MA8792-Quickstart-FR-FR.pdf 4,1 MB FR / FR
MAN Elektropneum. Stellungsregler MA8792-Standard-DE-DE.pdf 5,2 MB DE / DE
MAN Electropneumatic positioner MA8792-Standard-EU-EN.pdf 5,6 MB EN / EU
MAN Positionneur èlectropneum. MA8792-Standard-FR-FR.pdf 5,7 MB FR / FR
MAN Option Ext. position feedback MA8792-Supplement-EU-ML.pdf 1,1 MB EN,FR,DE / EU
MAN Software Communicator MA8920-Software-DE-DE.pdf 861,9 kB DE / DE
MAN Software Communicator MA8920-Software-EU-ML.pdf 849,6 kB EN / EU
MAN Software Communicator MA8920-Software-FR-FR.pdf 872,9 kB FR / FR
SOW PACTWARE4_1 SP1_.NET2_DTM Coll 4.1 PACTware4.1SP1_Buerkert.zip 252,4 MB
SOW PACTware 5.0 + DTM Collection 5.0 PACTware_setup_full_5.0.2.13.zip 315,9 MB
SOW Positioner DTM Collection 1.0 Positioner_DTM_Collection_V1.0.2.zip 13,8 MB
Position
Item No
Desrcripción
919061 round-plug fem. M12 8-pol. w.cable 2m PUR
919267 round-plug fem. M12 8-pol. w.cable 5m PUR