Bürkert - Close to you
Office /2
    • Main Office
      Bürkert South America S.A.
      Ruta 8. Km 17'500
      Edificio 700, local 704
      Montevideo UY-91600

      Teléfono (+598) 2518 3579
      E-Mail iragnf.yn@ohexreg.pbz
    • Main Office
      Bürkert-Contromatic Argentina S.A.
      Av. Cordoba 950, 10th Floor
      C1054AAV - Buenos Aires

      Teléfono +54 11 5648-6350
      E-Mail pbagnpgb.netragvan@ohexreg.pbz
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
We make ideas flow.
We make ideas flow.

    Caudalímetro por ultrasonidos sin display

    Type 8081 / Ident No. 560131

    Produkt-Foto Typ 8081

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8081
    • Produkt-Foto Typ 8081

    Flow sensor without display

    • Sensor de flujo por ultrasonidos que utiliza el método de tiempo de ciclo
    • Rango dinámico ≥ 1:250
    • Reducida pérdida de presión
    • No requiere tramos de estabilización en la entrada ni en la salida

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    El sensor de flujo por ultrasonidos, tipo 8081, es apropiado para medir el flujo del agua. Se compone de un módulo electrónico y de un racor de latón con tubo de medición integrado. La combinación de un regulador y de una válvula reguladora permite crear fácilmente tramos de regulación de flujo. La conexión eléctrica se efectúa con un conector de equipo de 5 pines M12 de varios polos. El sensor dispone de las salidas siguientes en función del modelo: - Una salida de pulsos o - Una salida de pulsos y una salida de corriente 4-20 mA. Todos los modelos se suministran con tres rangos de flujo diferentes: - Modelo QN 0,6 DN15: 0,06 a 20 l/min (tamaño nominal 0,6 m3/h, es decir, 10 l/min) - Modelo QN 1,5 DN15: 0,1 a 50 l/min (tamaño nominal 1,5 m3/h, es decir, 25 l/min) - Modelo QN 2,5 DN20: 0,16 a 82 l/min (tamaño nominal 2,5 m3/h, es decir, 41 l/min) - Modelo QN 3,5 DN25: 0,6 a 116 l/min (tamaño nominal 3,5 m3/h, es decir, 58 l/min) - Modelo QN 6,0 DN25: 1 a 200 l/min (tamaño nominal 6,0 m3/h, es decir, 100 l/min)


    Commodity Codes
    90261021
    país
    FR

    Technical attributes

    Nombre
    Value
    Unit
    Type 8081
    Flow rate (volume) Si
    Continuous measurement Si
    Dosing No
    Switch Si
    Display type sin pantalla
    Protection class measurement device (IP) 65
    DC voltage min. 12 V
    DC voltage max. 36 V
    Battery voltage No
    Precision of volume flow rate in relation to reading 1 %
    Temperature environment min 5 °C
    Temperature environment max 55 °C
    Temperature medium min 5 °C
    Temperature medium max 90 °C
    Pressure Class (PN) PN 16
    Dynamic viscosity min. 0 cP
    Dynamic viscosity max. 10 cP
    Min measured value of volume flow rate 0.06
    Max measured value of volume flow rate 20
    Measured value unit l/min
    Detection of flow direction Si
    Sensor type Ultrasonido
    Cable plug in delivery no servido
    Electrical connection 1 type Conector - M12
    Electrical connection 1 quantity 1 unid.
    Electrical connection 1 number of contacts 5 unid.
    Electrical connection 1 gender Macho
    Electrical connection 1 material PA (Poliamida)
    Electrical connection 1 seal material EPDM (Caucho de etileno propileno dieno)
    Output 1 digital type Transistor
    Output 1 digital version NC No
    Output 1 digital version NO No
    Output 1 digital transistor connection NPN Si
    Output 1 digital transistor connection PNP No
    Digital output 1 transistor contactless 0.7 A
    Electronics body material PPS (Sulfuro de polifenileno)
    Cover material PPS (Sulfuro de polifenileno)
    Seal housing/cover material Silicona
    Screw material Acero inoxidable
    Electronics body encapsulated Resina
    Parametrisation local No
    Parametrisation separate No
    Parametrisation fixed Si
    Diameter measuring tube (DN) 15 mm
    Fluidic port connection number 2 unid.
    Port connection 1 type Rosca exterior
    Port connection 1 thread type G
    Port connection 1 thread marking 3/4
    Port connection material Latón
    Measuring pipe material PES (Polietersulfona)
    Medium-contacting parts seal material EPDM (Caucho de etileno propileno dieno)
    Installation length 110 mm
    Weight 0,700000 kg
    Weight 0,700000 kg
    Show full table Collapse table

    Downloads

    Desrcripción
    Filename
    Filesize
    Language / Country
    3D_ANIMATION 3D-Animation - 8081 3D-PDF-DE-SD-USD6_pdf.pdf 3,8 MB DE
    3D_ANIMATION 3D-Animation - 8081 3D-PDF-EN-SD-USD6_pdf.pdf 3,7 MB EN
    DTS Durchflusssensor - Ultraschall DS8081-Standard-DE-DE.pdf 626,1 kB DE / DE
    DTS Flow sensor - Ultrasonic DS8081-Standard-EU-EN.pdf 648,4 kB EN / EU
    DTS Capteur de débit continu DS8081-Standard-FR-FR.pdf 345,2 kB FR / FR
    MAN Ultrasonic waves flow transmit MA8081-FlowTransmit-EU-ML.pdf 1,8 MB EN,FR,DE / EU
    Position
    Item No
    Desrcripción
    438680 Plug M12 5 positions 2m screened
    917116 flange sleeve M12 5pl, screwed cont.