    UPC Number
    Commodity Codes

    Technical attributes

    Type S056
    Temperature medium min -20 °C
    Temperature medium max 130 °C
    Pressure Class (PN) PN 16
    Dynamic viscosity min. 0 cP
    Dynamic viscosity max. 20000 cP
    Sensor type Magnético inductivo
    Magnetic inductive type Fullbore
    Construction fitting Compacto
    Fitting electronic interface para full bore
    Min measured value of volume flow rate 0
    Max measured value of volume flow rate 6000
    Measured value unit l/h
    Diameter measuring tube (DN) 15 mm
    Fluidic port connection number 2 unid.
    Port connection 1 type Clamp
    Port connection 1 size DN DN 20
    Port connection 1 inner diameter (mm) 16.65 mm
    Port connection 1 wall thickness (mm) 1.2 mm
    Port connection 1 outer diameter (mm) 19.05 mm
    Port connection 1 clamp outer diameter (mm) 25.4 mm
    Port connection 1 pipe standards 1 BS 4825-1
    Port connection 1 clamp BS 4825-3
    Port connection material Laiton
    Measuring pipe material Acero inoxidable
    Medium-contacting parts seal material FKM (Caucho fluorado)
    Electrode material Acero inoxidable
    Number of electrodes 2 unid.
    Roughness of pipe inside 0.8 µm
    Roughness of pipe outside 0.8 µm
    Installation length 128 mm
    Lining PTFE (Politetrafluoretileno)
    Protection type Fitting/Sensor (IP) 67
    Weight 5,225000 kg
    Weight 5,225000 kg
    Certification type ,
    Certification number
    Show full table Collapse table


    Language / Country
    DTS MID-Transmitter-Hygieneausfg. DS8056-Sanitary-DE-DE.pdf 1 MB DE / DE
    DTS Full Bore Magflowmeter DS8056-Sanitary-EU-EN.pdf 1 MB EN / EU
    DTS Débitmètre électromagnétique DS8056-Sanitary-FR-FR.pdf 994,4 kB FR / FR
    DTS MID-Elektronik DSSE56-Electronics-DE-DE.pdf 785,4 kB DE / DE
    DTS Magflow transmitter DSSE56-Electronics-EU-EN.pdf 970,7 kB EN / EU
    DTS Transmetteur de débit / Contrô DSSE56-Electronics-FR-FR.pdf 800,7 kB FR / FR
    MAN Full bore sensor-fitting MAS056-Fullbore-EU-ML.pdf 890 kB EN,FR,DE / EU