Transmisor de conductividad

Type 8222 / Ident No. 559620

Produkt-Foto Typ 8222

The depiction of the products may differ from the actual specific design.

  • Produkt-Foto Typ 8222
  • Produkt-Foto Typ 8222
  • Ersatzteil-Zeichnung Bürkert


Conductivity-transmitter

  • Salida analógica 4-20 mA
  • Conexión universal de proceso con tuerca de racor
  • Tres sensores diferentes de conductividad para un rango de medición amplio
  • Medición con compensación de temperatura

For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

Product description

El equipo, tipo 8222, de Bürkert es un transmisor compacto para medir la conductividad de líquidos. El transmisor 8222 dispone de un sensor. El sensor se fija al cuerpo con un pasador que no puede retirarse. El cuerpo, que aloja el módulo electrónico y el indicador desmontable, dispone de una tapa. El propio sensor se suministra con tres constantes de celda C diferentes y se compone de un sensor de temperatura Pt1000 y de dos electrodos de conductividad. Estos son de acero inoxidable en los sensores con la constante C de 0,01 o 0,1 y de grafito en los sensores con las constantes C de 1,0. La unidad se fija en el proceso con una tuerca de racor. El indicador opcional solo se necesita para la puesta en funcionamiento, la configuración y la calibración, o como indicador de valor de proceso. El equipo, tipo 8222, está disponible:- Con tres salidas programables: dos salidas de transistor y una salida de corriente 4-20 mA de 2 conductores - Con cuatro salidas programables: dos salidas de transistor y dos salidas de corriente 4-20 mA de 3 conductores El tipo 8222 convierte la señal de medición, muestra diferentes valores en unidades de medición distintas (si el indicador está conectado) y calcula las señales de salida, que se transmiten a través de uno o dos conectores M12.


Commodity Codes
90278011
país
FR

Technical attributes

Nombre
Value
Unit
Type 8222
PH No
Conductivity conductive Si
Conductivity inductive No
ORP No
Chlorine total No
Chlorine free No
Chlorine dioxide No
Oxygen No
Turbidity No
Temperature Si
Ozone No
Neutrino variant No
Construction device Compacto
Display type sin pantalla
Protection class measurement device (IP) 65/67
DC voltage min. 14 V
DC voltage max. 36 V
Operating supply type de 2 conductores
Measured value min 1 0.05 m
Measured value max 1 20 m
Measured value unit 1 µS/cm
Measuring accuracy 1 3
Unit of measuring accuracy 1 %
Measuring accuracy temperature (°C) 1 °C
Temperature environment min -10 °C
Temperature environment max 60 °C
Temperature medium min -20 °C
Temperature medium max 100 °C
Pressure Class (PN) PN 16
Temperature compensation Si
Fitting connection type Rosca interior
Fitting connection thread G
Fitting connection thread marking 1 1/2 pulgada
Electrical connection 1 type Conector - M12
Electrical connection 1 quantity 1 unid.
Electrical connection 1 number of contacts 5 unid.
Electrical connection 1 gender Macho
Electrical connection 1 material fundicion de zinc, niquelado
Electrical connection 1 seal material NBR (Caucho nitrilo)
Output analogue current functioning principle source Si
Output analogue current functioning principle drain Si
Output 1 type analog current 4-20 mA
Output 1 digital type Transistor
Output 1 digital transistor connection NPN Si
Output 1 digital transistor connection PNP Si
Digital output 1 transistor contactless 0.7 A
Output 2 digital type Transistor
Output 2 digital transistor connection NPN Si
Output 2 digital transistor connection PNP Si
Digital output 2 transistor contactless 0.7 A
Electronics body material Acero inoxidable
Cover material PPS (Sulfuro de polifenileno)
Protection lid material PC (Policarbonato)
Nut material PVDF (Polifluoruro de vinilideno)
Seal sensor/housing material EPDM (Caucho de etileno propileno dieno) Calidad alimentaria
Seal housing/cover material EPDM (Caucho de etileno propileno dieno)
Protection lid seal material EPDM (Caucho de etileno propileno dieno) Calidad alimentaria
Electrical connection plate material Acero inoxidable
Screw material Acero inoxidable
Electronics body encapsulated sin
Tropical climate version Si
Cell constant K=0,01
Number of electrodes 2 unid.
Finger material PVDF (Polifluoruro de vinilideno)
Parametrisation local Si
Parametrisation separate No
Parametrisation fixed No
Weight 0,800000 kg
Weight 0,800000 kg
Show full table Collapse table

Downloads

Desrcripción
Filename
Filesize
Language / Country
3D_ANIMATION 3D-Animation - 8222 3D-PDF-DE-SA-LFKD4_pdf.pdf 2,7 MB DE
3D_ANIMATION 3D-Animation - 8222 3D-PDF-EN-SA-LFKD4_pdf.pdf 2,7 MB EN
DTS Leitfähigkeits-Transmitter DS8222-Standard-DE-DE.pdf 920,2 kB DE / DE
DTS Conductivity Transmitter DS8222-Standard-EU-EN.pdf 918 kB EN / EU
DTS Transmetteur conductivité rési DS8222-Standard-FR-FR.pdf 904,8 kB FR / FR
DTS Conductivity Transmitter DS8222-Standard-US-EN.pdf 905,3 kB EN / US
DTS Transmisor conductividad 4-20 DS8222-Transmitter-ES-ES.pdf 2 MB ES / ES
DTS Leitfähigkeits-Transmitter DS8222-neutrino-DE-DE.pdf 1 MB DE / DE
DTS Conductivity Transmitter DS8222-neutrino-EU-EN.pdf 1,1 MB EN / EU
DTS Transmetteur conductivité DS8222-neutrino-FR-FR.pdf 1 MB FR / FR
DTS INSERTION Adapter DSS022-standard-DE-DE.pdf 915,5 kB DE / DE
DTS INSERTION Adaptor for Analysis DSS022-standard-EU-EN.pdf 915,5 kB EN / EU
MISC Flyer Element and Element neutrino Analytical Meters Types 8202, 8222, 8228 587,3 kB EN / EU
MAN GasketSet - ConnectingBox MA8202-GasketBox-EU-ML.pdf 140,3 kB EN,FR,DE / EU
MAN Quickstart 8202/8222 MA8202-Quickstart-EU-ML.pdf 6,2 MB EN,FR,DE / EU
MAN Mount Gasket on Thread. sensor MA8222-GasketMount-EU-ML.pdf 176,2 kB EN,FR,DE / EU
MAN Bedienungsanleitung 8222 MA8222-Manual-EU-DE.pdf 2,7 MB DE / EU
MAN Operating Instructions 8222 MA8222-Manual-EU-EN.pdf 2,8 MB EN / EU
MAN Manuel d'utilisation 8222 MA8222-Manual-EU-FR.pdf 2,8 MB FR / EU
MAN Operating Instruction Display MA8222-Manual-EU-ML.pdf 808,9 kB EN,FR,DE / EU
MAN neutrino conductivity MA8222-neutrino-EU-ML.pdf 3,9 MB EN,FR,DE / EU
MAN neutrino conductivity MA8222-neutrino-EU-ML.pdf 3,9 MB EN,FR,DE / EU
Position
Item No
Desrcripción
438680 Plug M12 5 positions 2m screened
Position
Item No
Desrcripción
01 561843 Transparent cover + o-seal EPDM